Page non trouvée

La page que vous souhaitez consulter a été déplacée ou n'existe plus.

Nous contacter

Pour vous aidez, nous avons effectué une recherche avec les mots contenu dans le lien que vous souhaitiez accéder :

About searching
  1. Physiologic responses to a staircase lung volume optimization maneuver in pediatric high-frequency oscillatory ventilation

    … Physiologic responses to a staircase lung volume optimization maneuver in pediatric high-frequency … during a staircase incremental–decremental pressure lung volume optimization maneuver in children on high-frequency … plethysmography values were used construct pressure–volume loops during the lung volume optimization maneuver. …

    10/02/2021 - 10:05

  2. Organizational factors associated with adherence to low tidal volume ventilation: a secondary analysis of the CHECKLIST-ICU database

    … factors associated with adherence to low tidal volume ventilation: a secondary analysis of the … Background Survival benefit from low tidal volume ( V _T) ventilation (LTVV) has been demonstrated for … Invasive ventilation, lung protection Tidal volume, low tidal volume ventilation Organizational …

    10/02/2021 - 10:05

  3. The impact of a multifaceted intervention including sepsis electronic alert system and sepsis response team on the outcomes of patients with sepsis and septic shock

    … a pre-intervention phase (January 01, 2011–September 24, 2012), intervention phase I (multifaceted intervention including e-alert, from September 25, 2012–March 03, 2013) and intervention phase II when SRT …

    10/02/2021 - 10:11

  4. Removal of totally implanted venous access ports for suspected infection in the intensive care unit: a multicenter observational study

    … sepsis in whom a TIVAP was removed between January 2012 and December 2014. We aimed (1) at determining the … (58 ± 14 years, 62% males) were included between 2012 and 2014. TIVAP-related infections were confirmed in 68 …

    10/02/2021 - 10:09

  5. Positive end-expiratory pressure titration with electrical impedance tomography and pressure–volume curve in severe acute respiratory distress syndrome

    … with electrical impedance tomography and pressure–volume curve in severe acute respiratory distress syndrome … tomography (EIT) and with ventilator-embedded pressure–volume loop in severe acute respiratory distress syndrome … above the lower inflection point on the static pressure–volume curve Results Patients in the EIT group were …

    10/02/2021 - 10:08

  6. Changes in dynamic arterial elastance induced by volume expansion and vasopressor in the operating room: a prospective bicentre study

    … Changes in dynamic arterial elastance induced by volume expansion and vasopressor in the operating room: a … as the ratio between pulse pressure variations and stroke volume variations, has been proposed to assess functional arterial load. We evaluated the evolution of Eadyn during volume expansion and the effects of neosynephrine infusion …

    10/02/2021 - 10:08

  7. The use of a novel cleaning closed suction system reduces the volume of secretions within the endotracheal tube as assessed by micro-computed tomography: a randomized clinical trial

    … use of a novel cleaning closed suction system reduces the volume of secretions within the endotracheal tube as … was measured by micro-computed tomography Results The volume of secretions in the ETTs from the cleaning group was … Biofilm Resistance to airflow Secretion volume Cross-sectional area Revues …

    05/08/2022 - 12:11

  8. Evaluation of least significant changes of pulse contour analysis-derived parameters

    … as positive when small variations in cardiac index, stroke volume index, stroke volume variation or pulse pressure variation occur. Pulse … allows continuous and real-time cardiac index, stroke volume, stroke volume variation and pulse pressure variation …

    10/02/2021 - 10:08

  9. Biotrauma during ultra-low tidal volume ventilation and venoarterial extracorporeal membrane oxygenation in cardiogenic shock: a randomized crossover clinical trial

    Biotrauma during ultra-low tidal volume ventilation and venoarterial extracorporeal membrane … unclear. We aimed to evaluate the impact of ultra-low tidal volume ventilation with tidal volume of 3 ml/kg predicted … MIR & AIC Copyright ©2021 The Author(s)

    05/08/2022 - 12:04

  10. Lung volumes and lung volume recruitment in ARDS: a comparison between supine and prone position

    Lung volumes and lung volume recruitment in ARDS: a comparison between supine and … analyze the variation in lung volumes and PEEP-induced lung volume recruitment with the change from supine position (SP) … 0.8 1 h before starting the protocol. End-expiratory lung volume (EELV) and functional residual capacity (FRC) were …

    10/02/2021 - 10:09